CDCBN - MAGNESIUM OXIDE & ALUMINUM OXIDE INSULATION PRODUCTS

  • MSDS: CDCBN
  • Manufacturer: WATLOW GORDON
  • Product Name: MAGNESIUM OXIDE & ALUMINUM OXIDE INSULATION PRODUCTS
  • National Stock Number: 5640-00F052754
Product Identification

Product ID:MAGNESIUM OXIDE & ALUMINUM OXIDE INSULATION PRODUCTS
MSDS Date:01/31/1993
FSC:5640
NIIN:00F052754
MSDS Number: CDCBN

Responsible Party
WATLOW GORDON
5710 KENOSHA ST
RICHMOND, IL 60071-5000
US

Emergency Phone: 815-678-2211

Info Phone: 815-678-2211

Preparer: ALAN HARNACKE

Cage: GO650

Contractor
WATLOW GORDON
500 RICHMOND, IL 60071-5000 US

Telephone: 815-678-2211

Cage: GO650

Ingredients

MANGANESE *96-4*

CAS: 7439-96-5

RTECS: OO9275000

OSHA PEL 5 MG/CUM

ACGIH TLV: 5 MG/CUM (DUST)


ALUMINUM OXIDE, BAUXITE, ALUMINA, DIALUMINUM TRIOXIDE

CAS: 1344-28-1

RTECS: BD1200000

OSHA PEL 15 MG/CUM

ACGIH TLV: 10 MG/CUM

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MILD IRRITANT. INHALATION: MAY
CAUSE IRRITATION OF MUCOUS MEMBRANE & AFFECT BREATHING CAPACITY.
INGESTION: MILD IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, DRYNESS, COUGHING, SHORTNESS OF
BREATH.

First Aid

First Aid:EYES: FLUSH W/WATER FOR 15 MINS. SKIN: REMOVE & WASH AFFECTED
AREAS. INHALATION: REMOVE TO FRESH AIR. GIVE CPR AS NEEDED.
INGESTION: GIVE LARGE AMOUNTS OF WATER. OBTAIN MEDICAL ATTENTION IN
ALL CASES.

Fire Fighting

Unusual Fire/Explosion Hazard:PRODUCT WILL NOT BURN.

Accidental Release

Spill Release Procedures:USE DRY CLEANUP PROCEDURES & AVOID DUSTING.

Exposure Controls

Respiratory Protection:RESPIRATOR REQUIRED IF RECOMMENDED EXPOSURE
LIMITS ARE EXCEEDED, USE NIOSH/OSHA APPROVED. WET CUTTING
&/GRINDING WILL PREVENT DUSTING OF PRODUCT.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Eye Protection:SAFETY GLASSES
Supplemental Safety and Health

Chemical Properties

Solubility in Water:INSOLUBLE

Stability

Stability Indicator/Materials to Avoid:YES

Disposal

Waste Disposal Methods:DISPOSE/USE STANDARD LANDFILL METHODS
IAW/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.